Fill Water
Important
The first time you use your AirDresser, it will use more water than the Refill Tank can hold, so this message will appear on the first cycle you run. This is normal.
- The Refill Tank needs more water. (Make sure to always use filtered water.) Fill it up to the MAX line, reinsert it, and then touch Start to continue the cycle.
- This message can also appear if the Refill Tank is not properly inserted.
Read more
Read less
Empty Water
- The drain tank is full. Empty the drain tank, reinsert it, and then touch Start to continue the cycle.
- This message can also appear if the drain tank is not properly inserted.
Read more
Read less
Door Open
The door is open. Close it, and then touch Start to continue the cycle.
Read more
Read less
Abnormality Detected
Something is inside the AirDresser that shouldn't be. Open the door and make sure there are no children or pets inside the AirDresser. Then close the door and touch Start to continue the cycle.
Read more
Read less
Wi-Fi Not Connected
See our troubleshooting for
Cannot connect to SmartThings.
Read more
Important
For any of the following codes, or for any codes not listed, visit our
Support Center to request service.
Read less
tC5
The resistance of the Compressor thermistor is too low or high.
Read more
Read less
tC7
The resistance of the Eva In thermistor is too low or high.
Read more
Read less
tC8
The resistance of the Eva Out thermistor is too low or high.
Read more
Read less
tCC
The resistance of the Steam kit thermistor is too low or high.
Read more
Read less
tCd
The resistance of the Duct Rear Air thermistor is too low or high.
Read more
Read less
tCF
The resistance of the Duct Front Air thermistor is too low or high.
Read more
Read less
dC
Open the door and operate the AirDresser.
Read more
Read less
1C1
The level sensor in the steam chamber is malfunctioning.
Read more
Read less
4C3
The water supply from the steam chamber is malfunctioning.
Read more
Read less
HC3
The steam heater is malfunctioning.
Read more
Read less
HC6
The temperature of the steam heater is too high.
Read more
Read less
5C
- The drain pump is not working.
- The drain chamber fully-filled sensor is not working.
Read more
Read less
5C2
Check the water supply chamber.
Read more
Read less
5C3
Check the drain chamber.
Read more
Read less
5C4
Check both the water supply/drain chamber.
Read more
Read less
bC2
A button is held for over 30 seconds.
Read more
Read less
HC
The temperature of the compressor is too high.
Read more
Read less
7C1
The upper damper is malfunctioning.
Read more
Read less
7C2
The lower damper is malfunctioning.
Read more
Read less
FC4
The lower fan motor is malfunctioning.
Read more
Read less
3CF (3CF1, 3CF2, 3CF4, 3CF5, 3CF6, 3CF7)
- The upper BLDC fan motor terminal is not properly connected.
- The upper BLDC fan motor is constrained or defective.
- The main PBA is defective.
Read more
Read less
9C1, 9C2
- The power status is defective.
- Error occurs when too low or too high voltage is supplied.
- A plug-type outlet is used.
- The main PBA is defective.
Read more
Read less
3CA, 3CA1, 3CA2, 3CA3, 3CA4
- The compressor motor is defective.
- The compressor motor is not properly connected.
- The main PBA is defective.
Read more
Read less
AC
There is a communication error.
Read more
Read less
AC6
- A signal between the main PBA and inverter PBA is not detected.
- The wiring between the main PBA and inverter PBA is wrong.
Read more
Read less